Whether you need to heat your warehouse, machine shop, or other hard-to-heat spaces, the SunStar StarGlo ceramic infrared heater provides both the fuel efficiency of radiant heat and the installation flexibility you need . . . and all at a comfortable price
The SunStar StarGlo
SGM Series
Millivolt Standing Pilot
CERAMIC INFRARED HEATER
The SunStar StarGlo is the answer for spot or area heating and for total building heating needs. It is also ideal for the replacement of existing ceramic heaters, over 10 million of which have been sold in North America since the early 1950’s. The SunStar StarGlo heats like the sun by transferring radiant heat energy directly into the area to be heated and creating a warm comfort zone at the floor level. This extremely efficient method of heating can result in fuel savings of between 30% and 50% when compared to forced air convection heating.
WIDE VARIETY OF APPLICATIONS
SunStar StarGlo Ceramic heaters are ideal for many heating needs. The best applications are those where doors open and close frequently and in buildings where ceiling heights are above twelve feet. These flexible SunStar infrared heaters can meet most commercial and industrial heating needs.
Ceramic Infrared Heating is the answer for spot or area heating and for total building heating needs. It is also ideal for the replacement of existing ceramic heaters. SunStar Ceramic Heaters heat like the sun by transferring radiant heat energy directly into the area to be heated and creating a warm comfort zone at the floor level. This extremely efficient method of heating can result in fuel savings of between 30% and 50% when compared to forced air convection heating.
Capacities from 26,000 to 104,000 Btu/hr
Does not require external electrical power to operate
Millivolt standing pilot operation with 100% gas shut-off safety control
Aluminized steel construction
Aluminum reflectors
Compact size for UPS shipping
Suitable for horizontal or angle mount up to 30°
Natural or propane gas
Indirect vented operation
Protective radiant screen included
Optional reflector extensions available
CSA design certified
Application
Remote Locations
Farm Buildings
Maintenance Buildings
Shops
Warehouses
Service Areas
Pump Houses
Not Recommended for Residential Use
About This Unit
Millivolt Standing Pilot Ignition System
1/2 NPT Female Gas Connection
Model: SGM3-N1
Gas Type: Natural Gas
Input BTU/HR: 26,000
Minimum Mounting Height:12'
Does Not Require Electricity to Operate
SG Supply Requirements
Gas Type: Natural Gas
Burner Pressure (Water Column): 3.5"
Supply Pressure (Water Column) MIN:4.5"
Supply Pressure (Water Column) MAX: 14"
Ignition Type: Millivolt Standing Pilot
Gas Connection: 1/2” NPT Female
SG Clearances to Combustibles (Mounted Horizontally)
Model: SGM3
Back: 24"
Back w/Reflector Extension: 36"
Sides: 24"
Sides w/Reflector Extension: 36"
Ceiling: 24"
Ceiling w/Reflector Extension: 36"
Below: 48"
Below w/Reflector Extension: 126"
SG Clearances to Combustibles (Mounted 30° Angle)
Model: SGM3
Back: 8"
Back w/Reflector Extension: 12"
Sides: 24"
Sides w/Reflector Extension: 36"
Ceiling: 32"
Ceiling w/Reflector Extension: 36"
Below: 48"
Below w/Reflector Extension: 126"
WARNING: This heater is not approved for any residential installation including home, residential, garage, or recreational use (mobile home, RV’s, campers, etc.). For residential garage applications sunstar recommends SIR Series vented tube heaters.
** This unit is Natural Gas**
COMBUSTION AIR AND VENTILATION
Combustion air and venting requirements for all gas-fired heating equipment must be provided per the National Fuel Gas Code NFPA54 and CAN B149 or the authority having jurisdiction over the installation. Refer to Installation and Operation Instructions for further information. An indirect vented installation requires a minimum ventilation flow of 4 CFM per 1000 Btu/hr of total installed heater capacity on natural gas by either gravity or power ventilation (4.18 CFM per 1000 Btu/hr on propane). For indirect vented applications, building exhaust openings must be located above the level of the heaters and the inlet air openings must be located below the level of the heaters.
FOR YOUR SAFETY OPERATE SUNSTAR GAS INFRARED HEATERS WITH PROPER CARE AND OBSERVE ALL SAFETY PRECAUTIONS. Installation and service must be performed by a licensed contractor. The installation must conform with local codes. In the absence of local codes, the installation must conform with the National Fuel Gas Code ANSI Z223.1 (latest edition also known as NFPA 54) or CAN B149 installation codes (latest edition). These codes are available from ANSI, 1430 Broadway, New York, NY 10018, the National Fire Protection Association, Inc., Batterymarch Park, Quincy, MA 02269 or C.S.A. 55 Scarsdale Road, Toronto, Ontario M3B 2R3 Canada.