Sunstar SG6 LP Ceramic Heater 60,000 BTU
SGM Typical Applications
Not Recommended for Residential Use
Technical Specifications
Model
|
Gas Type
|
Input Btu/hr
|
No. of Burners
|
Minimum Mounting
Height (ft.) |
SG6-Natural Gas
|
NAT
|
60,000
|
2
|
13
|
SG6-LP Propane
|
LP
|
65,000
|
2
|
13
|
SG Supply Requirements
Gas Type
|
Burner Pressure |
Supply Pressure (water column)
|
|
|
|
Minimum
|
Maximum
|
Natural Gas
|
6"
|
7"
|
14"
|
Propane Gas
|
10"
|
11"
|
14"
|
Direct Spark Ignition System. 120 VAC. 0.40 Amp. Includes 120/24 V Transformer.
1/2 NPT Female Gas Connection.
SG Clearances to Combustibles (In Inches)
Model
|
Mounted Horizontally
|
Mounted at 30° angle
|
|||||||
|
Sides
|
Ceiling
|
Below
|
w/Reflector |
Below
|
w/Reflector
Extension |
Front
|
w/Reflector
Extension |
Rear
|
SG6
|
49
|
49
|
99
|
138
|
99
|
138
|
49
|
69
|