ICM291 Direct Spark Ignition Control Board LH33WP003
Furnace Control Control - replacement for Carrier LH33WP003/3A control boards
- Low cost, direct replacement for Carrier: LH33WP003A
- Direct Spark Ignition (DSI) control board
- Microprocessor-based
- Controls combustion, blower and indorr fan motors; spark ignitor; and the gas valve
- Monitors timing, trial for ignition, flame sensing and lockout
- 100% lockout safety feature
- Compatible with LP or Natural Gas
- Status LED for fault
Specifications
- Control Voltage: 24 VAC (18-30 VAC), 60Hz
- Line Voltage: 208/230 VAC, 60Hz
Timing
- Pre-Purge: 45 seconds
- Trial for Ignition: 5+2 seconds
- Retry Period: Every 20 seconds for 15 minutes
- Lockout: Manual reset
- Post-Purge: 45 seconds
LED Indicators
- Red LED: Steady ON-normal operation; Flashing-fault codes
Input
- Power: RT and C
- Thermostat Interface: R,W, and G
- Safety Switches: RS, LS, and CS
- Combustion Motor Hall Effect Sensor
- Flame Sensing
Outputs
- Spark
- Gas Valve: GV
- Combustion Motor: CM
- Blower Motor: BM
- Indoor Fan Motor: IFO