.Replaces Old Honeywell Board #s: ST9101A1006, ST9101A1014, ST9101A1022, ST9120A1006, ST9120A2004, ST9120B1005, ST9120C1012, ST9120C1020, ST9120C2002, ST9120C2010, ST9120C2028, ST9120C3000, ST9120C3018, ST9120C4008, ST9120C4016, ST9120C4040, ST9120C4057, ST9120C5005, ST9120C5013, ST9120D3009, ST9120G2008, ST9120G2016, ST9120D2024, ST9120G2032, ST9120G4004, ST9120G4012, ST9120G4038, ST9120U1003, ST9141A1002, ST9141A1028, ST9141B1001, ST9150A1003, ST9150B2000, ST9150B2018, ST9150B2026, ST9150B2034, ST9160A1002, ST9160B1001, ST9160B1019, ST9160B1027, ST9160B1035, ST9160B1043, ST9160B1050, ST9160B1068, ST9160B1076, ST9160B1084, ST9160C1000, ST9160C1018
Features |
Central appliance wiring point simplifies appliance assembly and service. Fixed or field-adjustable heat fan on delay; field adjustable heat fan off delay. |
Product Specifications | |
|
Description | Universal Electronic Fan Timer with adjustable heat fan on, heat fan off, cool fan on, and cool fan off | Application | Integrates control of combustion blower and circulating fan operations for a gas warm air appliance | Electrical Ratings | 18 to 30 Vac | Heat Fan On Delay | adj. 30, 60 sec (set at 30 sec) | Heat Fan Off Delay | adj. 60, 120, 150, 180 sec (set at 120 sec) | Cool Fan On Delay | adj. 4, 30 sec (set at 4 sec) | Cool Fan Off Delay | adj. 30, 60 sec (set at 30 sec) | Temperature Range, Ambient (F) | -40 F to +175 F | Temperature Range, Ambient (C) | -40 C to +79 C | Approvals, Underwriters Laboratories Inc | Listed: Report MP466 | Approvals, Canadian Standards Association | Certified: File No. LR95329-17 | Replaces | all ST9101's, all ST9120's, all ST9141's, and all ST9160's | Tradeline Value | Universal Tradeline
| |